Services

Please contact me if you have any engineering or scientific issues.

My services for electric power industry:

  • Expertise of projects
  • Work to find the causes of equipment damage
  • Lecturing to improve the skills of your employees
  • Participation in seminars and conferences as a speaker, expert, moderator
  • Management of master’s theses
  • Management of PhD’s theses
  • Management of scientific research
  • Development of high-voltage equipment
  • Development of new calculation methods
  • Creation of regulatory documents
  • Creation of software

The area of my interest relates to the following:

  • Cable and overhead lines
  • Electromagnetic processes, transients
  • Overvoltages and protection against them
  • Metal-oxide surge arresters (MOA)
  • Shunt reactors and power transformers processes
  • SF6 and vacuum circuit breaker switching processes
  • The neutral grounding in electrical networks

The list of my calculation options:

  • 6-500 kV cables, selection of core and screen cross-section
  • Screens bonding/grounding schemes for 6-500 kV cable lines
  • Thermal conditions of 6-500 kV cable lines
  • Mechanical parameters of pipes (ducts) for laying 6-500 kV cables
  • Magnetic field of cable lines
  • Electric and magnetic fields of overhead lines
  • Voltages induced on cable and overhead lines
  • Personnel safety issues when working on cable or overhead lines
  • Parameters (R,L,C,G,Z,T) of cable and overhead lines
  • Grounding of cable screen cross-bonding nodes
  • Grounding of transition points on mixed cable and overhead lines
  • Lightning overvoltages of 6-750 kV lines and switchgears
  • Switching overvoltages of 6-750 kV lines and switchgears
  • Optimal location and main characteristics of 6-750 kV surge-arresters
  • Arc, resonant, ferro-resonant overvoltages
  • Neutral grounding methods, selection of the reactor and/or resistor
  • Measures to limit aperiodic currents on 110-750 kV lines with shunt reactors
  • Currents and voltages at automatic reclosure on 110-750 kV lines with shunt reactors
  • Induced potential of the self-supporting fiber-optic cable on overhead line
  • Thermal resistance of lightning protection wires on overhead lines
  • ATP/EMTP modelling, including statistical
  • Other relevant issues

Working conditions:

  • The contract is drawn up officially, in accordance with the requirements of European legislation
  • On my side, the contract can be signed on behalf of Portuguese or Hungarian companies
  • The contract and reporting materials are drawn up in English (there may be other options)